- Pokaż wszystko - Pokaż różnice - Wróć | MIERNIK LABORATORYJNY UT-801 UNI-T | MIERNIK LABORATORYJNY UT-803 UNI-T | MIERNIK LABORATORYJNY UT-8802E UNI-T |
| | | |
| 433.07 PLN 532.68 PLN
| 785.36 PLN 965.99 PLN
| 773.30 PLN 951.16 PLN
|
Pomiar napięcia DC: | 200 mV ± (0.5% + 2) @ 0.1 mV, 2 V ± (0.5% + 2) @ 1 mV, 20 V ± (0.5% + 2) @ 10 mV, 200 V ± (0.5% + 2) @ 100 mV, 1000 V ± (0.8% + 3) @ 1 V | 600 mV ± (0.6% + 2) @ 0.1 mV, 6 V ± (0.3% + 2) @ 0.001 V, 60 V ± (0.3% + 2) @ 0.01 V, 600 V ± (0.3% + 2) @ 0.1 V, 1000 V ± (0.5% + 3) @ 1 V | 200 mV ± (0.1% + 5) @ 0.01 mV, 2 V ± (0.1% + 3) @ 0.1 mV, 20 V ± (0.1% + 3) @ 0.001 V, 200 V ± (0.1% + 3) @ 0.01 V, 1000 V ± (0.2% + 5) @ 0.1 V |
Pomiar napięcia AC: | 2 V ± (0.8% + 3) @ 1 mV, 20 V ± (1.0% + 4) @ 10 mV, 200 V ± (1.0% + 4) @ 100 mV, 1000 V ± (1.0% + 4) @ 1 V | 600 mV @ 0.1 mV : ± (0.6% + 5) @ 40 Hz ... 50 kHz ± (1.0% + 5) @ 50 kHz ... 100 kHz 6 V @ 0.001 V : ± (0.6% + 5) @ 40 Hz ... 1 kHz ± (1.0% + 5) @ 1 kHz ... 10 kHz ± (3.0% + 5) @ 10 kHz ... 100 kHz 60 V @ 0.01 V : ± (0.6% + 5) @ 40 Hz ... 1 kHz ± (1.5% + 5) @ 1 kHz ... 10 kHz ± (3.0% + 5) @ 10 kHz ... 20 kHz ± (8.0% + 5) @ 20 kHz ... 100 kHz 600 V @ 0.1 V : ± (0.6% + 5) @ 40 Hz ... 1 kHz ± (3.5% + 5) @ 1 kHz ... 10 kHz 1000 V @ 1 V : ± (1.2% + 3) @ 40 Hz ... 1 kHz ± (3.0% + 3) @ 1 kHz ... 3 kHz | 2 V @ 100 µV ± (0.5% + 20) @ 40 Hz ... 1 kHz 20 V @ 1 mV ± (0.5% + 20) @ 40 Hz ... 1 kHz 200 V @ 10 mV ± (0.5% + 20) @ 40 Hz ... 1 kHz 750 V @ 0.1 V ± (0.8% + 40) @ 40 Hz ... 1 kHz |
Pomiar prądu DC: | 200 µA ± (0.8% + 2) @ 0.1 µA, 2 mA ± (0.8% + 2) @ 0.001 mA, 20 mA ± (0.8% + 2) @ 0.01 mA, 200 mA ± (0.8% + 2) @ 0.1 mA, 10 A ± (2.0% + 4) @ 0.01 A | 600 µA ± (0.5% + 3) @ 0.1 µA, 6000 µA ± (0.5% + 3) @ 1 µA, 60 mA ± (0.5% + 3) @ 0.01 mA, 600 mA ± (0.8% + 3) @ 0.1 mA, 10 A ± (1.2% + 3) @ 0.01 A | 200 µA ± (0.5% + 20) @ 10 nA, 2 mA ± (0.5% + 20) @ 100 nA, 20 mA ± (0.5% + 20) @ 1 µA, 200 mA ± (0.5% + 20) @ 10 µA, 20 A ± (1.5% + 40) @ 1 mA |
Pomiar prądu AC: | 2 mA ± (1.0% + 3) @ 0.001 mA, 20 mA ± (1.0% + 3) @ 0.01 mA, 200 mA ± (1.0% + 3) @ 0.1 mA, 10 A ± (2.5% + 5) @ 0.01 A | 600 µA @ 0.1 µA : ± (1.0% + 5) @ 40 Hz ... 10 kHz ± (2.0% + 5) @ 10 kHz ... 15 kHz 6000 µA @ 1 µA : ± (1.0% + 5) @ 40 Hz ... 10 kHz ± (2.0% + 5) @ 10 kHz ... 15 kHz 60 mA @ 0.01 mA : ± (1.0% + 5) @ 40 Hz ... 10 kHz ± (2.0% + 5) @ 10 kHz ... 15 kHz 600 mA @ 0.1 mA : ± (1.0% + 5) @ 40 Hz ... 10 kHz ± (3.0% + 5) @ 1 kHz ... 10 kHz 10 A @ 0.01 A : ± (2.0% + 6) @ 40 Hz ... 5 kHz | 2 mA @ 0.1 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz 20 mA @ 1 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz 200 mA @ 10 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz 20 A @ 1 mA ± (2% + 40) @ 45 Hz ... 400 Hz |
Pomiar rezystancji: | 200 Ω ± (0.8% + 3) @ 0.1 Ω, 2 kΩ ± (0.8% + 3) @ 1 Ω, 20 kΩ ± (0.8% + 3) @ 10 Ω, 200 kΩ ± (0.8% + 3) @ 100 Ω, 2 MΩ ± (0.8% + 3) @ 1 kΩ, 20 MΩ ± (1.2% + 5) @ 10 kΩ | 600 Ω ± (0.8% + 3) + rezystancja przewodów pomiarowych @ 0.1 Ω, 6 kΩ ± (0.5% + 2) @ 0.001 kΩ, 60 kΩ ± (0.5% + 2) @ 0.01 kΩ, 600 kΩ ± (0.5% + 2) @ 0.1 kΩ, 6 MΩ ± (0.8% + 2) @ 0.001 MΩ, 60 MΩ ± (1.2% + 3) @ 0.01 MΩ | 200 Ω ± (0.5% + 10) + rezystancja przewodów pomiarowych @ 0.01 Ω, 2 kΩ ± (0.5% + 10) @ 0.1 Ω, 20 kΩ ± (0.5% + 10) @ 1 Ω, 200 kΩ ± (0.5% + 10) @ 10 Ω, 2 MΩ ± (0.5% + 10) @ 100 Ω, 200 MΩ @ 1 kΩ |
Pomiar pojemności: | 20 nF ± (4% + 3) @ 0.01 nF, 2 µF ± (4% + 3) @ 0.001 µF, 200 µF ± (5% + 5) @ 0.1 µF | 6 nF ± (2.5% + 5) @ 0.001 nF, 60 nF ± (2.5% + 5) @ 0.01 nF, 600 nF ± (2.0% + 5) @ 0.1 nF, 6 µF ± (2.0% + 5) @ 0.001 µF, 60 µF ± (2.0% + 5) @ 0.01 µF, 600 µF ± (3.0% + 4) @ 0.1 µF, 6 mF ± (5.0% + 4) @ 0.001 mF | 20 nF ± (2.5% + 10) @ 1 pF, 200 nF ± (1.5% + 10) @ 10 pF, 2 µF ± (1.5% + 10) @ 100 pF, 20 µF ± (1.5% + 10) @ 1 nF, 200 µF ± (1.5% + 10) @ 10 nF, 2 mF ± (1.5% + 10) @ 100 nF, 20 mF ± (10% + 10) @ 1 µF, 100 mF @ 10 µF |
Pomiar indukcyjności: | | | |
Pomiar częstotliwości: | 2 kHz ± (1.5% + 5) @ 1 Hz, 200 MHz ± (1.5% + 5) @ 100 Hz | 6 kHz ± (0.1% + 3) @ 0.001 kHz, 60 kHz ± (0.1% + 3) @ 0.01 kHz, 600 kHz ± (0.1% + 3) @ 0.1 kHz, 6 MHz ± (0.1% + 3) @ 0.001 MHz, 60 MHz ± (0.1% + 3) @ 0.01 MHz , | 200 Hz ± (1% + 5) @ 0.01 Hz, 2 kHz ± (1% + 5) @ 0.1 Hz, 20 kHz ± (1% + 5) @ 1 Hz, 200 kHz ± (1% + 5) @ 10 Hz, 2 MHz ± (1% + 5) @ 100 Hz, 10 MHz ± (1% + 5) @ 1 kHz, 5 % ... 99 % ± (1.5% + 2) @ 10 Hz ... 10 kHz |
Pomiar temperatury: | -40 °C ... -20 °C ± (8% + 5) @ 1 °C, -20 °C ... 0 °C ± (1.2% + 4) @ 1 °C, 0 ... 100 °C ± (1.2% + 3) @ 1 °C, 100 ... 1000 °C ± (2.5% + 2) @ 1 °C | °C :
-40 °C ... 0 °C ± (8.0% + 5) @ 1 °C , 0 °C ... 400 °C ± (1.0% + 3) @ 1 °C , 400 °C ... 1000 °C ± (1.5% + 3) @ 1 °C , °F :
-40 °F ... 32 °F ± (8.0% + 5) @ 1 °F , 32 °F ... 752 °F ± (1.5% + 5) @ 1 °F , 752 °F ... 1832 °F ± (2.5% + 5) @ 1 °C | |
Automatyczna zmiana zakresów pomiarowych: | | | |
hFE: | | | |
Test diody: | | | |
Sygnalizacja ciągłości obwodu: | | | |
Sprawdzanie stanów logicznych TTL: | | | |
RS-232: | | | |
USB: | | | |
Wybrane cechy: | Duży, czytelny wyświetlacz LCD z podświetleniem Hold - zatrzymanie wskazania miernika Estetyczne i solidne wykonanie | Duży, czytelny wyświetlacz LCD z podświetleniem Możliwość pomiaru napięcia zmiennego z uwzględnieniem składowej stałej (funkcja pomiaru AC+DC) Hold - zatrzymanie wskazania miernika Estetyczne i solidne wykonanie | Bardzo wysoka dokładność pomiarów Wyświetlacz EBTN REL - tryb pomiaru względnego Zapis wartości MAX / MIN Hold - zatrzymanie wskazania miernika Port USB Estetyczne i solidne wykonanie |
Zasilanie: | 6 x Bateria 1.5V, typ R14/LR14 (brak w zestawie), 9 V DC / 200 mA (zasilacz w komplecie) | 6 x Bateria 1.5V, typ R14/LR14 (brak w zestawie), 220 V AC | 110 V AC / 120 V AC / 220 V AC / 240 V AC - wybierane przełącznikiem |
Waga: | 1.61 kg | 1.88 kg | 3.43 kg |
Wymiary: | 306 x 243 x 107 mm | 306 x 243 x 107 mm | 320 x 265 x 110 mm |
Producent / Marka: | UNI-T | UNI-T | UNI-T |
Gwarancja: | 2 lata | 2 lata | 2 lata |